Cygnus Thickness Gauge MK-2 - 23
Description
Driver Information
| Driver | Cygnus Thickness Gauge MK-2 | Interface Type | Driver Class Type | ||
|---|---|---|---|---|---|
| UTC Driver | No | Input / Output | Input | Executable | DrvCygnus.exe |
| Related Systems |
| ||||
| Related Pages | |||||
Coding Notes
Decoding Notes
According to the Cygnus M5 ROV Operating Manual the ROV Gauge has a fixed Velocity of Sound value of 6400 m/s. You must re-scale the received thickness value for the velocity of sound required.
For example when measuring carbon steel with a velocity of 5920 m/s you will need to apply the following conversion factor: True Thickness = Received Thickness * 5920/640.
Encoding Notes
Not applicable.