Dredging - Production

Production observations or calculations can be manually overruled by the user.
CtrSessionSetupDredgingProd.jpg

Multiple overrule parameters may be selected:

Production Setup


Overrule Density Solid

Option is not available and the Density Solid can only be changed under

Dumping - Material Type

.

Overrule Density Water

Enter a density for the water (fresh or salt water).

Overrule Density In Situ

Option is not available and the Density in Situ can only be changed under

Dumping - Material Type

.

Overrule Production

Enter a production value in cubic meters / second.

Count PMO when below Design

Count the times that the Poor Mixture Overboard valve is used when the dredge head is in between a tolerance and the design.
The tolerance that needs to be specified lies above the design.

Trip Volume


Volume Mode

Manual - Total Value - This volume will be used to update the sounding grid when the dumping is done and will overrule the production that was calculated during the dredging operation.
Manual - Per Bay - This volume will be used to update the sounding grid when the dumping is done when dump bays are used.
Typically this is used for side stone dumpers.
Automatic - This will use the production that was calculated during the dredging operation.

Total Volume

Enter the volume when Volume Mode was set to Manual - Total Value.

Bay x Volume

Enter the volume when Volume Mode was set to Manual - Per Bay.

Return to: Session Setup - Dredging