Dredging - Production
Production observations or calculations can be manually overruled by the user.
Multiple overrule parameters may be selected:
Production Setup | |
---|---|
Overrule Density Solid | Option is not available and the Density Solid can only be changed under Dumping - Material Type. |
Overrule Density Water | Enter a density for the water (fresh or salt water). |
Overrule Density In Situ | Option is not available and the Density in Situ can only be changed under Dumping - Material Type. |
Overrule Production | Enter a production value in cubic meters / second. |
Count PMO when below Design | Count the times that the Poor Mixture Overboard valve is used when the dredge head is in between a tolerance and the design. The tolerance that needs to be specified lies above the design. |
Trip Volume | |
Volume Mode | Manual - Total Value - This volume will be used to update the sounding grid when the dumping is done and will overrule the production that was calculated during the dredging operation. Manual - Per Bay - This volume will be used to update the sounding grid when the dumping is done when dump bays are used. Typically this is used for side stone dumpers. Automatic - This will use the production that was calculated during the dredging operation. |
Total Volume | Enter the volume when Volume Mode was set to Manual - Total Value. |
Bay x Volume | Enter the volume when Volume Mode was set to Manual - Per Bay. |
Return to: Session Setup - Dredging