Production observations or calculations can be manually overruled by the user.

Multiple overrule parameters may be selected:

Production Setup
Overrule Density SolidOption is not available and the Density Solid can only be changed under Dumping - Material Type.
Overrule Density WaterEnter a density for the water (fresh or salt water).
Overrule Density In SituOption is not available and the Density in Situ can only be changed under Dumping - Material Type.
Overrule ProductionEnter a production value in cubic meters / second.
Count PMO when below DesignCount the times that the Poor Mixture Overboard valve is used when the dredge head is in between a tolerance and the design.
The tolerance that needs to be specified lies above the design.
Trip Volume
Volume ModeManual - Total Value - This volume will be used to update the sounding grid when the dumping is done and will overrule the production that was calculated during the dredging operation.
Manual - Per Bay - This volume will be used to update the sounding grid when the dumping is done when dump bays are used.
Typically this is used for side stone dumpers.
Automatic - This will use the production that was calculated during the dredging operation.
Total VolumeEnter the volume when Volume Mode was set to Manual - Total Value.
Bay x VolumeEnter the volume when Volume Mode was set to Manual - Per Bay.

Return to: Session Setup - Dredging