Qinsy 9.11.0 - Improvements

This page shows an overview of improvements grouped by topic.


Online

Session Setup - Storage - Grid - Simplified view

The Grid page in Session Setup › Storage now has a simplified view for the Systems view modes. Each system type has its own tab, and a simpler drop-down list sets what is stored in the grid. This makes it easier to set up a grid.

Session Setup - Velocity Profile - Refraction warning

9.10.3 and before
When you added a sound velocity profile while refraction was disabled, Qinsy only showed a warning that refraction was disabled.

9.11.0
The warning now lists the systems for which refraction is disabled and asks whether you want to enable it. When you click Yes, refraction is enabled for all Multibeam systems. Other system types are not changed. The warning is also shown when folder monitoring for SVP files is active.


Survey Manager

Areas - Warning for complex polygons

Some calculations in the Survey Manager, such as a volume calculation for an area, can give an incorrect result when the area polygon crosses itself (a complex polygon). The Survey Manager now checks areas for this, and shows a warning when complex polygons are brought in through Areas › Import or through Extract from file with Areas as target type. Areas with a complex polygon cannot be used in a volume calculation.


Back to Release