Hypack USB Fixbox - 17
Description
Driver to be used to generate an event output on a Hypack USB Fixbox. Output will be every fix event in an online session of Qinsy.
The fixbox is connected to the PC via a USB connection. An appropriate virtual COM port driver needs to be installed before using the fixbox.
Fixbox is output only, it can not be used to receive events like the QPS trigger boxes can.
Driver Information
Driver | Hypack USB Fixbox | Interface Type | Driver Class Type | ||
---|---|---|---|---|---|
No | Input / Output | Executable | DrvOutFix.exe 99 | ||
Related Systems |
| ||||
Related Pages |
Interfacing Notes
Standard USB cable may be used.
System Configuration
The fixbox is shipped together with a CD with software. Follow installation guidelines as supplied by Hypack.
A virtual COM port driver should be installed on PC. The virtual com port will get a port number during the installation, this port should be selected in DbSetup for the Fixbox interfacing.
Database Setup
In DB Setup, add an "Closure Output system" and select the "Hypack USB Fixbox" driver, set communication parameters to 9600,n,8,1.
Update rate will not be used!
The events will occur on every Controller fix.
Further, leave the Closure Parameters Tab sheet for what it is. Settings will not be used for this driver.
Online
When Online in the Controller, closures will only be generated after you enable the Closure Generation option on the third page of the Session Wizard.
These settings are not saved by the Controller due to safety reasons.
Drivers IO Notes
Same driver is also used for interfacing to QPS Trigger boxes.
The Drivers.io option is a figure that informs the driver of the fixbox type.
Option | Fixbox type |
---|---|
1 | QPS Triggerbox MkI |
2 | QPS Triggerbox MkII |
3 | QPS Triggerbox MkIII |
4 | QPS Triggerbox MkVI |
99 | Hypack USB Fixbox |