DM-0420

Description


Driver Information

Driver

Cygnus Thickness Gauge MK-2

Interface Type


Driver Class Type


UTC Driver question mark

No

Input / Output

Input

Executable

DrvCygnus.exe

Related Systems

Related Pages



Coding Notes

Decoding Notes

According to the Cygnus M5 ROV Operating Manual the ROV Gauge has a fixed Velocity of Sound value of 6400 m/s. You must re-scale the received thickness value for the velocity of sound required.

For example when measuring carbon steel with a velocity of 5920 m/s you will need to apply the following conversion factor: True Thickness = Received Thickness * 5920/640.

Encoding Notes