Qimera Sound Velocity Correction Process
This process will be initiated automatically by the Dynamic Workflow engine whenever the following occurs:
- SVP files are edited - here
- SVP selection strategies or processing configuration settings are modified - here
- Vessel configuration is edited, either manually or through application of patch test or wobble analysis results, including changes to TPU parameters - here
- Motion sensor, surface sound speed or depth/pressure (AUV only) data is edited - here
- Motion sensor, surface sound speed or depth/pressure (AUV only) data is re-prioritized - here
- Blocking parameters are changed - here
When this occurs, the multibeam observations of range and angle are re-integrated with all the supporting ancillary information, including the SVP, to re-compute the sonar relative sounding footprint location. The position of the CoG is also re-navigated in 3D using the specified vertical referencing method. If edits to the surface sound speed data are done, the multibeam beam angles are re-computed prior to the ray trace using the new surface sound speed.
Return to: Dynamic Workflow