Skip to main content
Skip table of contents

Qinsy 9.6.2 - Known Issues

The QPS team is continuously improving Qinsy to implement new functionality and documentation.
Unfortunately, there are a number of known issues in our software release.

These software issues will be solved in future maintenance releases.

Survey Manager - Static Grid - Plan view settings - Reference settings changed from minus to plus at upgrade

Problem
Between Qinsy 9.5.x and Qinsy 9.6.0 the Operation setting changed.
So if you set that to Active minus reference 9.5.x, it will have changed to Active plus reference in Qinsy 9.6.0 and 9.6.1.

Qinsy 9.5.x

Qinsy 9.6.0

image-20240111-123237.png
image-20240111-123225.png

If you changed/set in in 9.6.0, it will be the same in 9.6.1.

However we changed this back again so now the following will happen in 9.6.2 if you set it to Acitve minus reference in the following versions:

  • 9.5.x → Active minus reference (tick)

  • 9.6.0 → Active plus reference (error)

  • 9.6.1 → Active plus reference (error)

Unfortunately this was the only way to resolve this bug.

Solution
Set it correctly so it will keep working correctly in 9.6.2 and all subsequent versions.

Displays - Navigation - CAD

Converting a design file into a background file will not show lines when the start and end point of a line are outside the view. (Viewing Panel)

Recommendation
Do not convert design files into background files. If lines from a design are needed in the Navigation Display, then create a dedicated background file.

Displays - Navigation - CAD Survey Manager

The QPS team encountered a memory problem with CAD files which contain many complex blocks.

Recommendation
Do not use CAD files which contain many complex blocks. This bug will be solved in a future maintenance release.

Displays - Navigation - ENC Survey Manager

Both the Survey Manager and Navigation Display are not Per monitor DPI aware.
With two monitors, each with different display scales, the scale on the secondary monitor will not be correct.
This also affects the way the ENCs are drawn.

Recommendation
Please vote on: FQI-605

Survey Manager - Plan View - ENC

ENCs produced by Rijkswaterstaat for the Dutch province of Zeeland and ENCs produced by the Netherlands Hydrographic office cannot be displayed simultaneously due to the different usage levels and compilation scales of both producers.

For more information and updates: https://vaarweginformatie.nl/frp/main/#/page/infra_enc

Survey Manager - Sounding Grid - Import Geoid Model

Since Qinsy 9.5.0 it is possible again to import most Geoid models into a sounding grid.
The only Geoid models that cannot be imported yet, are the ones that cross the dateline (+180° East/West).

Please let us know if you do need to import such a model.


Back to Release

JavaScript errors detected

Please note, these errors can depend on your browser setup.

If this problem persists, please contact our support.