Skip to main content
Skip table of contents

Qinsy 9.5.5 - Known Issues

The QPS team is continuously improving Qinsy to implement new functionality and documentation.
Unfortunately, there are a number of known issues in our software release.

These software issues will be solved in future maintenance releases.

Drivers - SSS - Edgetech - Data lagging behind

Problem
Recently we received tickets from customers were the Edgetech data seems to be lagging behind.
The data is still properly recorded.

Workaround
For now the only workaround seems to be to lower the update rate by setting a wider range.

Planned fix
This is planned to be fixed in Qinsy 9.6.0 feature release. This since the changes were to extensive to add to a maintenance release.
If you run into this problem, please reach out to QPS support.

Drivers - MBES - KMALL - Crash

Problem
In Qinsy 9.5.5 we added support for Dual Head + Dual Swath data. This was tested together with Kongsberg.
However it seems we overlooked something which results in crashes.

Workaround
We have created a patch that can be installed.
The link below includes the component and a read me file that explains how to set it up.

Qinsy_9.5.5_KMALL_DrvQPSFreeBase.zip

Planned fix
This is planned to be fixed in Qinsy 9.5.6.

Online - Session Setup - Log file tab is missing

Problem
We found a bug were the Logfile tab is missing when a you open the Controller (go Online) and encounter a warning message.

This could be a message about:

  • Deprecated driver;

  • Missing COM port

If you get a different message, please contact QPS support.

Workaround
The workaround, depending on the message that you see, would either be to

  • Update the template by choosing different drivers.

  • Or by removing systems that are connected to COM ports that are no longer in use.

We do suggest to save that in a copy of the template as we plan to fix this.

Planned fix
This is planned to be fixed in Qinsy 9.5.6.

Displays - Navigation - CAD

Converting a design file into a background file will not show lines when the start and end point of a line are outside the view. (Viewing Panel)

Recommendation:
Do not convert design files into background files. If lines from a design are needed in the Navigation Display, then create a dedicated background file.

Displays - Navigation - CAD Survey Manager

The QPS team encountered a memory problem with CAD files which contain many complex blocks.

Recommendation:
Do not use CAD files which contain many complex blocks. This bug will be solved in a future maintenance release.

Displays - Navigation - ENC Survey Manager

Both the Survey Manager and Navigation Display are not Per monitor DPI aware.
With two monitors, each with different display scales, the scale on the secondary monitor will not be correct.
This also affects the way the ENCs are drawn.

Recommendation:
Please vote on: FQI-605

Survey Manager - Plan View - ENC

ENCs produced by Rijkswaterstaat for the Dutch province of Zeeland and ENCs produced by the Netherlands Hydrographic office cannot be displayed simultaneously due to the different usage levels and compilation scales of both producers.

For more information and updates: https://vaarweginformatie.nl/frp/main/#/page/infra_enc

Survey Manager - Sounding Grid - Import Geoid Model

Since Qinsy 9.5.0 it is possible again to import most Geoid models into a sounding grid.
The only Geoid models that cannot be imported yet, are the ones that cross the dateline (+180° East/West).

Please let us know if you do need to import such a model.


Back to Qinsy 9.5.5 Release page

JavaScript errors detected

Please note, these errors can depend on your browser setup.

If this problem persists, please contact our support.