Skip to main content
Skip table of contents

How-to I/O Driver Editor

This How-to will explain how to create your own driver.

Important: Update files first

With Qinsy 9.4.x all drivers have been updated.
In order to use drivers, created in older Qinsy versions, you will need to open them in the I/O Driver Editor and click through the settings (Next, Next, Finish).


The I/O Driver Editor is technically referred to as IniFileEditor.exe

On this page:

Purpose

  1. Creation and/or editing of generic drivers for ASCII input
    1. This data string connection can either be through standard RS232 format,
    2. Or through network UDP
    3. Or via an OPC connection
  2. Decoding of multiple systems from a single string
  3. Decoding of multiple strings on a single COM port
    1. For each string that needs to be decoded, a separate driver needs to be created

Adding the I/O Driver Editor to the Console

In case you do not see the I/O Driver Editor in the bottom pane, you can add it with the following steps:

  • Right-click in the bottom pane and select "Add / Remove QPS Programs..."
  • Tick the checkbox

Creating a driver

Delimited strings

  1. Under Type: select 'Generic Input'
    Press the 'New' button to create a new file


  2. General Information
    1. Enter a name
      • Start characters can be placed in the name for easy identification
        • This is the identifier and indicates where Qinsy should start decoding
    2. Define whether it will be decoded via:
      1. Serial
      2. UDP
      3. OPC - How-to I/O OPC Driver
    3. Select System Types

      Press Next>
  3. Set the Decoding Parameters
    1. String Parameters
      • Start characters
        • This is the identifier and indicates where Qinsy should start decoding
      • Termination character
        • For most strings this is either a Line Feed (LF) or a Carriage Return (CR)
      • Separation character
        • This is often a ",": Comma
      • Minimum length
        • Minimum number of characters that will be decoded
      • Maximum length
        • Maximum number of characters that will be decoded


    2. Checksum parameters
      • In case there is a checksum at the end of a string, enabling this option will give you 4 methods of decoding it:
        • NMEA
        • Modulo
        • CRC16
        • CRC32



      F1 Help inside I/O Driver Editor

      For an explanantion of the various Methods, use the inline F1 Help function of the I/O Driver Editor.

    3. Timetag parameters
      • In case the time in the string is in GPS time, a correction to UTC can be applied
      • The option to use the date from the system is enabled by default and the date from a data string is not decoded
        (See the F1 Help function of the I/O Driver Editor for further explanation)

      Press Next>

  4. Set the Decoding Properties
    1. Observations
      • Each system type has its own list of observation types
        Highlight a system and by clicking "Add"/"Remove" you can select the observations that need to be decoded


      • Encoding: this can either be ASCII, the Sine of Angle or EXPONENTIAL
      • Mask: For a position latitude message, for example, it can be written in several different ways:
        • Degrees minutes seconds
        • Decimal degrees
        • For a System Date, when the 'Use system date' was disabled on the previous page, masks for the date in the string can be selected:
        • Day Month Year
        • Year Month Day
      • Field
        • If you use a separation character, this will define the fields:
      • Length: not applicable for delimited strings
      • Multiplication Factor: the observation will be multiplied by this value and the result will be used in Qinsy
      • Maximum value: If it is higher, it will not be decoded
      • Minimum value: If it is lower, it will not be decoded
      • Observation name: This is the name you'll see in the template setup and online
      • Quality Indicator: If a quality indicator is available under a system that supports multiple observations, it can be assigned to the system-observation is belongs to. 
        This can be done by selecting the observation and selecting it from the drop down menu, as displayed in the picture below.

Fixed length strings

For strings that have a fixed length, the steps for creating a driver are slightly different:

  1. Same as Delimited strings
  2. Same as Delimited strings
  3. Make sure to set the Separation character to None


  4. On the last page you can now define where you want to start decoding (Column) and how many characters the observation has (Length).

Adding the driver to the Template

The newly created driver can be found in the drivers list. The name will start with 'Generic' followed the name you entered.

For each system type you defined, you can select this driver. They should then all be able to connect to the same COM or UDP port.

Tip

In case you have modified observation settings in the I/O Driver setup, you might need to remove it from your template and add it again.

We suggest to first check this online in the Observation Physics Display and if it is not recorded to re-add the driver.


Online

The Observation Physics display will enable you to check if the observations are decoded correctly:

Storage location

If you want to use the drivers that you created on another PC, you will need to copy them to the correct directory:

C:\Users\Public\Documents\QPS\Qinsy\Drivers\Definitions\Input

A button named 'Open directory' is available in the main display that directly brings you to the correct folder: